Albi Cote FRL-X Fire Resistive Material (IFRM)
Albi Cote FRL-X is a water-based, intumescent fire-resistive interior finish coating designed to combine aesthetics with performance. It provides a smooth, durable finish that achieves a Class A interior finish rating in accordance with ASTM E84 and IBC requirements, ensuring superior flame spread and smoke development control. Suitable for use on a wide range of substrates, FRL-X offers designers and specifiers the assurance of code compliance while maintaining architectural appeal. Its environmentally friendly, low-VOC formulation, along with versatile application methods, makes it an ideal solution for both new construction and retrofit projects where fire safety and design integrity are equally important.
Benefits
- Class A Interior Finish – Tested per ASTM E84 and compliant with IBC Section 803 for low flame spread and smoke development ratings.
- Thin Film Profile – Provides a smooth, architectural finish without significantly altering the aesthetics of the substrate.
- Versatile Application – Can be applied to a wide range of substrates including gypsum wallboard, wood, and other interior building materials.
- Durable Performance – Resistant to cracking, flaking, and chalking, ensuring long-term protection and appearance.
- Environmentally Friendly – Water-based, low-VOC formulation suitable for sustainable building projects.
- Ease of Use – Spray, roller, or brush application options allow for efficient installation on new construction or retrofit projects.
- Code Compliance & Assurance – Backed by UL classification and manufacturer testing to provide confidence in meeting fire safety requirements.
Product Uses
Albi Cote FRL-X is recommended as a decorative finish for the protection for the protection of combustible surfaces such as eaves, wood, fiberboard, plywood, or particle board, and as supplementary low flame spread and low smoke density protection when applied to plaster, gypsum wallboard, or cinder block. Albi Cote FRL-X is specially designed for application to combustible areas of public assembly such as restaurants, nursing homes, schools, corridors, stairwells, and similar areas where odor-free, quick drying features are desired.
Fire Tests & Approvals
In order to meet the performance and durability criteria set forth by the American Institute of Architects (AIA) and other major industry specifying organizations, Albi Cote FRL-X has undergone the most rigorous testing in accordance with the world’s most demanding safety protocols.
Test for Surface Burning Characteristics of Building Materials
Test Methods for Surface Burning Characteristics of Building Materials, such as UL 723, ULC S102, and ASTM E84 evaluates how materials contribute to flame spread and smoke generation when exposed to fire. Conducted in a 25-foot tunnel furnace (Steiner Tunnel), the test measures two key indices: the Flame Spread Index (FSI), which indicates the rate at which flames travel across the material’s surface, and the Smoke Developed Index (SDI), which reflects the density of smoke produced. Results are compared against reference materials and classified into performance groups (Class A, B, or C), providing critical data for building code compliance on interior finishes.
Albi Cote FRL-X provides a Class A rating when evaluated in accordance with these standards
UL Classification Mark
The UL Classification Mark indicates compliance with global requirements as it relates to a specific risk or casualty. With the Classification service, UL determines that a manufacturer has demonstrated the ability to produce a product complying with UL’s requirements with respect to one or more of the following:
- Specific risk, e.g., casualty, fire, etc.
- Performance under specific conditions
- Compliance with regulatory codes
- Compliance with specific standards such as international standards
- Other condition, as determined by UL
All of the products carrying a UL Classification Mark are covered by UL’s Follow-Up Services program to verify that products carrying the UL Classification Mark continue to be manufactured in compliance with UL’s safety requirements.
Major Specification and Approval Compliance
Albi Cote® FRL-X provides designers with a solution for achieving a Class A interior finish rating, in accordance with the requirements of Chapter 8 of the International Building Code (IBC).
- MasterSpec®, Section 078123 APPLIED FIREPROOFING (AIA)
- MasterFormat® 2014, Section 07 81 00 Applied Fireproofing (CSC,CSI)
- Unified Facilities Guide Specification, UFGS 07 81 00 Spray-Applied Fireproofing (USACE, NAVFAC, AFCEC, NASA)
- Master Construction Specifications, Number 07 81 00 Applied Fireproofing (VA)
- Code of Federal Regulations, Title 40 Protection of the Environment (EPA)
- PBS-P100, Facilities Standards for the Public Buildings Services (GSA)
Specifications Assistance
Provides the design professional with assistance in generating the most current, accurate, and comprehensive construction specifications.
Support
Our unsurpassed technical support and recognized applicator network.